The EECF has a wide variety of instrumentation for independent use by UW-Madison faculty and students.
To schedule training, please visit the Training Page
To reserve an instrument, please visit the Reservations Page
The lab has a single Flow Cytometer system.
- Manufacturer: BD Biosciences
- Model: FACSCalibur
Users are required to take the “Introduction to Flow Cytometry lecture series” provided by the by UWCCC Flow Lab (cost is $107.04 for UW-Madison faculty and students; NOTE: cost is set by the UWCCC and may change). This is a 3-part class (90 minutes each) that provides a great overview of flow cytometry and instrumentation.



The lab has multiple GC (Gas Chromatography) systems for the analysis of organic compounds in water, solvent, or gas.
- Manufacturer (all): Shimadzu Scientific.
(1) GC #3 – w/ ECD (Electron Capture Detector) and Restek RTX-624 (30m) column or user provided column(s)
(2) GC #4 (for gas analysis) w/ both FID (Flame Ionization Detector) and TCD (Thermo Conductivity Detector); installed with system-specific Packed Columns
(3) GC #5 – w/ FID (Flame Ionization Detector) and a variety of columns to choose from [Stabilwax-DA (15m), Stabilwax-DA (30m), Restek RTX-5 (30m)] or user provided column(s)
Samples must be extracted into a solvent (unless using the Stabilwax column on GC5 for fatty acid analysis – can analyze water samples). A set of calibration standards should be prepared in the same solvent.
The lab has a single GC-MS (Gas Chromatography-Mass Spectrometry) system for the analysis of organics.
- Manufacturer: Shimadzu Scientific
- Model: GC-2020 with QP2010S Mass Spectrometer detector
- Column: Restek RXI-5MS (30m, 0.25mm ID, 0.25um) or user provided column
Samples must be extracted into a solvent. A set of calibration standards should be prepared in the same solvent.
The lab has a single HPLC (High Performance Liquid Chromatography) system for the analysis of a variety of analytes from anions to sugars.
- Manufacturer: Shimadzu Scientific
- Model: AT vp system
- Detectors: Diode Array (UV-Vis); Refractive Index (RI); Fluorescence
- Column(s): Restek Ultra Aqueous C18 (4.6 x 150mm, 5um); Bio-Rad Aminex HPX-87H (300 x 7.8 mm, 9um) or user provided column(s)
All samples must be filtered with a 0.45um filter and in 1.7-2.0mL autosampler vials. A set of calibration standards should be prepared under the same conditions as the samples.
The lab has a single ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) system for the analysis of Metals.
- Manufacturer: Varian
- Model: Vista-MPX ICP-OES
Liquid samples must be filtered using a 0.45um filter, adjusted with concentrated Nitric Acid (HNO3) to pH <2, and brought to the lab in 15mL disposable centrifuge tubes (like THESE). A set of calibration standards should be prepared under the same conditions (pH <2 with HNO3, 15mL tubes).
The lab has a single epi Fluorescent microscope for both fluorescence and bright field microscopy.
- Manufacturer: Zeiss
- Model: Imager Z2