Instrumentation

The EECF has a wide variety of instrumentation for independent use by UW-Madison faculty and students.

To schedule training, please visit the Training Page

To reserve an instrument, please visit the Reservations Page

The lab has a single Micropore Size and Chemisorption Analyzer (aka BET) for gas sorption analysis.

  • Manufacturer: Quantachrome
  • Model: autosorb IQ
  • Brochure

The lab has a single Freezer Dryer / Lyophilizer for removal of water from samples. Samples should be frozen prior to using this instrument (a -80 freezer is available while instrument cools to the working temperature).

  • Manufacturer: LabConco
  • Model: FreezeZone 2.5
  • Details

 

The lab has a single FTIR (Fourier Transform Infrared) spectrometer for the analysis of liquids and solids using the attached diamond ATR accessory. Solid samples (not films) should be milled or ground to a powder for best performance.

  • Manufacturer: Thermo Scientific
  • Model: Nicolet iS10
  • Accessory: Smart iTX (diamond ATR – attenuated total reflectance)
  • Brochure
GC #3
GC #3
GC4 - GC-2014 (Gas Analysis)
GC#4
GC5 - GC-FID
GC#5
GC-HS aka GC #6
GC-HS aka GC #6

The lab has multiple GC (Gas Chromatography) systems for the analysis of organic compounds in water, solvent, or gas.

  • Manufacturer (all): Shimadzu Scientific.

(1) GC #3 – w/ ECD (Electron Capture Detector) and Restek RTX-624 (30m) column or user provided column(s). [Installed Fall 2023]

(2) GC #4 (for gas analysis) w/ both FID (Flame Ionization Detector) and TCD (Thermo Conductivity Detector); installed with system-specific Packed Columns.

(3) GC #5 – w/ FID (Flame Ionization Detector) and a variety of columns to choose from [Stabilwax-DA (15m), Stabilwax-DA (30m), Restek RTX-5 (30m)] or user provided column(s).

(4) GC-HS (aka GC #6) – w/ FID (Flame Ionization Detector) and Headspace Autosampler for the analysis of liquid or headspace samples ; installed with a Restek RTX-5 (30m) column or user provided column(s). [Installed Fall 2023]

Samples must be extracted into a solvent (unless using the Stabilwax column on GC5 for volatile fatty acid analysis – can analyze water samples). A set of calibration standards should be prepared in the same solvent.

GC-MS

The lab has a single GC-MS (Gas Chromatography-Mass Spectrometry) system for the analysis of organics.

  • Manufacturer: Shimadzu Scientific
  • Model: GC-2020 with QP2010S Mass Spectrometer detector
  • Column: Restek RXI-5MS (30m, 0.25mm ID, 0.25um) or user provided column

Samples must be extracted into a solvent. A set of calibration standards should be prepared in the same solvent.

The lab has a single HPLC (High Performance Liquid Chromatography) system for the analysis of a variety of analytes from anions to sugars.

  • Manufacturer: Shimadzu Scientific
  • Model: AT vp system
  • Detectors: Diode Array (UV-Vis); Refractive Index (RI); Fluorescence
  • Column(s): Restek Ultra Aqueous C18 (4.6 x 150mm, 5um); Bio-Rad Aminex HPX-87H (300 x 7.8 mm, 9um) or user provided column(s)
  • New Pump, Controller, and Software Fall 2023
  • New Autosampler Fall 2024

All samples must be filtered with a 0.45um filter and in 1.7-2.0mL autosampler vials. A set of calibration standards should be prepared under the same conditions as the samples.

The lab has a single IC (Ion Chromatography) system for the analysis of anions OR cations.

  • Manufacturer: Thermo Scientific
  • Model: Dionex Aquion
  • Detectors: Suppressed Conductivity
  • Installed Fall 2023

All samples must be filtered with a 0.45um filter (minimum volume 5mL). A set of calibration standards should be prepared under the same conditions as the samples. Sample vials and caps are provided.

The lab has a single ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) system for the analysis of Metals.

  • Manufacturer: Agilent
  • Model: 5800 VDV ICP-OES
  • Installed: December 2022

Liquid samples must be filtered using a 0.45um filter, adjusted with concentrated Nitric Acid (HNO3) to pH <2, and brought to the lab in 15mL disposable centrifuge tubes (like THESE). A set of calibration standards should be prepared under the same conditions (pH <2 with HNO3, 15mL tubes).

The lab has a single epi Fluorescent microscope for both fluorescence and bright field microscopy.

  • Manufacturer: Zeiss
  • Model: Imager Z2

The lab has a single Laser Diffraction Particle Size Analyzer. Samples should be in powder form for best performance.

  • Manufacturer: Beckman Coulter
  • Model: LS 13 320
  • Details

The lab has a single Thermogravimetric Analyzer (TGA).

  • Manufacturer: TA Instruments
  • Model: TGA 550
  • Details

 

The lab has a single Total Organic Carbon (TOC) – Total Nitrogen (TN) Instrument for Liquid OR Solid sample analysis.

  • Manufacturer: Shimadzu Scientific
  • Model: TOC-L + TNM-L + SSM-5000A (solids)
  • Autosampler (liquid samples): ASI-L (68 x 40mL vial capacity)
  • Installed: December 2023 / Spring 2024
  • Details / Brochure

Liquid Samples (up to 1000mg/L C or N): This instrument can measure Total Carbon (TC), Inorganic Carbon (IC), Non-Purgeable Organic Carbon (NPOC), and Total Organic Carbon (TOC) using a non-dispersive infrared detector (NDIR). The instrument can also measure Total Nitrogen (TN) using a Chemiluminescence detector. Minimum sample volume needed is 20mL. Vials and caps are provided, but must be rinsed and left for cleaning post analysis. [NOTE: vials/caps are washed in the lab dishwasher. Vials are then dried in a 103 degree C oven overnight, cooled, recapped, and returned to the lab. Caps/septa are not put into the oven.] *** If you require high sensitivity, low concentration (< 1 mg C/L) – you may want to consider the high sensitivity TOC instrument in this Core facility. ***

Solid Samples (or liquid samples with suspended solids) (up to 30mg C): This instrument can measure Total Carbon (TC) and Inorganic Carbon (IC) using the SSM-5000A Solid Sample Combustion unit.

This is an accordion element with a series of buttons that open and close related content panels.

Fourier Transform Infrared Spectrometer (FTIR)

The lab has a single FTIR (Fourier Transform Infrared) spectrometer for the analysis of liquids and solids using the attached diamond ATR accessory. Solid samples (not films) should be milled or ground to a powder for best performance.

  • Manufacturer: Thermo Scientific
  • Model: Nicolet iS10
  • Accessory: Smart iTX (diamond ATR – attenuated total reflectance)
  • Brochure

Freeze Dryer (aka Lyophilizer)

The lab has a single Freezer Dryer / Lyophilizer for removal of water from samples. Samples should be frozen prior to using this instrument (a -80 freezer is available while instrument cools to the working temperature).

  • Manufacturer: LabConco
  • Model: FreezeZone 2.5
  • Details

Gas Chromatography (GC-FID, GC-HS-FID, GC-FID-TCD, GC-ECD)

GC #3
GC #3
GC4 - GC-2014 (Gas Analysis)
GC#4
GC5 - GC-FID
GC#5
GC-HS aka GC #6
GC-HS aka GC #6

The lab has multiple GC (Gas Chromatography) systems for the analysis of organic compounds in water, solvent, or gas.

  • Manufacturer (all): Shimadzu Scientific.

(1) GC #3 – w/ ECD (Electron Capture Detector) and Restek RTX-624 (30m) column or user provided column(s) [Installed Fall 2023]

(2) GC #4 (for gas analysis) w/ both FID (Flame Ionization Detector) and TCD (Thermo Conductivity Detector); installed with system-specific Packed Columns

(3) GC #5 – w/ FID (Flame Ionization Detector) and a variety of columns to choose from [Stabilwax-DA (15m), Stabilwax-DA (30m), Restek RTX-5 (30m)] or user provided column(s)

(4) GC-HS (aka GC #6) – w/ FID (Flame Ionization Detector) and Headspace Autosampler for the analysis of liquid or headspace samples ; installed with a Restek RTX-5 (30m) column or user provided column(s). [Installed Fall 2023]

Samples must be extracted into a solvent (unless using the Stabilwax column on GC5 for fatty acid analysis – can analyze water samples). A set of calibration standards should be prepared in the same solvent.

Gas Chromatography-Mass Spectrometry (GCMS)

GC-MS

The lab has a single GC-MS (Gas Chromatography-Mass Spectrometry) system for the analysis of organics.

  • Manufacturer: Shimadzu Scientific
  • Model: GC-2020 with QP2010S Mass Spectrometer detector
  • Column: Restek RXI-5MS (30m, 0.25mm ID, 0.25um) or user provided column

Samples must be extracted into a solvent. A set of calibration standards should be prepared in the same solvent.

High Performance Liquid Chromatography (HPLC)

The lab has a single HPLC (High Performance Liquid Chromatography) system for the analysis of a variety of analytes from anions to sugars.

  • Manufacturer: Shimadzu Scientific
  • Model: AT vp system
  • Detectors: Diode Array (UV-Vis); Refractive Index (RI); Fluorescence
  • Column(s): Restek Ultra Aqueous C18 (4.6 x 150mm, 5um); Bio-Rad Aminex HPX-87H (300 x 7.8 mm, 9um) or user provided column(s)
  • New Pump, Controller, and Software Fall 2023
  • New Autosampler Fall 2024

All samples must be filtered with a 0.45um filter and in 1.7-2.0mL autosampler vials. A set of calibration standards should be prepared under the same conditions as the samples.

Ion Chromatography (IC)

The lab has a single IC (Ion Chromatography) system for the analysis of anions OR cations.

  • Manufacturer: Thermo Scientific
  • Model: Dionex Aquion
  • Detectors: Suppressed Conductivity
  • Installed Fall 2023

All samples must be filtered with a 0.45um filter. A set of calibration standards should be prepared under the same conditions as the samples. Sample vials and caps are provided.

Inductively Couple Argon Plasma Spectrometer (ICP-OES)

The lab has a single ICP-OES (Inductively Coupled Plasma – Optical Emission Spectrometry) system for the analysis of Metals.

  • Manufacturer: Agilent
  • Model: 5800 VDV ICP-OES
  • Installed: December 2022

Liquid samples must be filtered using a 0.45um filter, adjusted with concentrated Nitric Acid (HNO3) to pH <2, and brought to the lab in 15mL disposable centrifuge tubes (like THESE). A set of calibration standards should be prepared under the same conditions (pH <2 with HNO3, 15mL tubes).

Micropore Size and Chemisorption Analyzer (aka BET)

The lab has a single Micropore Size and Chemisorption Analyzer (aka BET) for gas sorption analysis.

  • Manufacturer: Quantachrome
  • Model: autosorb IQ
  • Brochure

 

Microscope (epi Fluorescence, Bright Field)

The lab has a single epi Fluorescent microscope for both fluorescence and bright field microscopy.

  • Manufacturer: Zeiss
  • Model: Imager Z2
  • New Camera and Software (July 2022)

 

Particle Size Analyzer

The lab has a single Laser Diffraction Particle Size Analyzer. Samples should be in powder form for best performance.

  • Manufacturer: Beckman Coulter
  • Model: LS 13 320
  • Details

 

Thermogravimetric Analyzer (TGA)

The lab has a single Thermogravimetric Analyzer (TGA).

  • Manufacturer: TA Instruments
  • Model: TGA 550
  • Details

 

Total Organic Carbon-Total Nitrogen (TOC-TN)

The lab has a single Total Organic Carbon (TOC) – Total Nitrogen (TN) Instrument for Liquid OR Solid sample analysis.

  • Manufacturer: Shimadzu Scientific
  • Model: TOC-L + TNM-L + SSM-5000A (solids)
  • Autosampler (liquid samples): ASI-L (68 x 40mL vial capacity)
  • Installed: December 2023 / Spring 2024
  • Details / Brochure

Liquid Samples (up to 1000mg/L C or N): This instrument can measure Total Carbon (TC), Inorganic Carbon (IC), Non-Purgeable Organic Carbon (NPOC), and Total Organic Carbon (TOC) using a non-dispersive infrared detector (NDIR). The instrument can also measure Total Nitrogen (TN) using a Chemiluminescence detector. Minimum sample volume needed is 20mL. Vials and caps are provided, but must be rinsed and left for cleaning post analysis. [NOTE: vials/caps are washed in the lab dishwasher. Vials are then dried in a 103 degree C oven overnight, cooled, recapped, and returned to the lab. Caps/septa are not put into the oven.] *** If you require high sensitivity, low concentration (< 1 mg C/L) – you may want to consider the high sensitivity TOC instrument in this Core facility. ***

Solid Samples (or liquid samples with suspended solids) (up to 30mg C): This instrument can measure Total Carbon (TC) and Inorganic Carbon (IC) using the SSM-5000A Solid Sample Combustion unit.